DRAFT: Arbor Lakes Data Center Network Attachment

University schools, colleges and departments may install and operate their own machines in the Arbor Lakes data center. Access to the space is provided by IT Central Services UMCE. Contact UMCE to make arrangements for access to space.

Network service is provided by IT Central Services ITCom. For units that attach their LANs to the UMnet backbone (provided by ITCom) service is available in two models. The unit may attach their machines to an ITCom provided distribution switch on a per port basis or the unit may have a distribution switch attached that is for their sole use.


Individual Station Attachments in Arbor Lakes Data Center

In this model, machines in the data center may attach to an ITCom provided distribution switch. This configuration is effective for smaller installations. Since there will also be other unit's equipment on this switch the unit will be sharing network bandwidth, to a degree, with other units.

ITCom Responsibilities

  • Provide and install a LAN port which is attached to UMnet
  • Provide and install one station cable per LAN port, extended to the units machine location
  • Support and maintain all ITCom provided equipment in a fashion similar to that of a backbone router port (See UMnet Backbone Service Agreement)
  • Performance of the connections is as described in the UMnet Backbone SA
  • Provide one UMnet IP address per machine

Unit Responsibilities

  • Acquire access, space, rack(s), electrical power, etc. directly from IT Central Services UMCE
  • Install machines
  • Operate machines on the network as described in the UMnet Backbone SA
  • Provide contact information as described in the UMnet Backbone SA
  • Do not run multiple machines off of individual attachments

Rates per LAN Port for Units that Attach to UMnet
Installation
Price per
Port
Monthly
Rate per
Port*
Annual
Internet
Utilization
**
10/100 Ethernet $500 $0 variable
1G Ethernet - Copper not available NA NA
1G Ethernet - Fiber not available NA NA

* Units that attach their LANs to UMnet already fund UMnet operations
** Covers actual traffic (quantity of bits) to and from the Internet


Backbone Network Attachment in Arbor Lakes Data Center

In this model, the unit selects and purchases a distribution switch from those that ITCom supports. ITCom will install, operate and maintain the switch. The units may use the ports on the distribution switch as desired. This configuration is effective for larger installations.

ITCom Responsibilities

  • Extend two 1Gbps Ethernet links to the distribution switch in the units "cage"
  • Operate, support and maintain the distribution switch and all ITCom provided equipment as described in the UMnet Backbone SA
  • Performance of the connections is as described in the UMnet Backbone SA
  • Provide a group of UMnet IP addresses as requested via the Network Information Change Request (NICR) form

Unit Responsibilities

  • Select and purchase a distribution switch (see UMnet Backbone SA)
  • Acquire data center access, space, rack(s), electrical power, etc. directly from ITCS/UMCE
  • Install machines
  • Provide and install station cables
  • Operate machines on the network as described in the UMnet Backbone SA
  • Provide information as requested in the Network Information Change Request (NICR) form

Rates for Backbone Attachment for Units that attach to UMnet